Machine Specification
Combination X-Ray and Checkweigher
Combination X-ray and Checkweigher Specifications
Display/configuration of the following data:
- Storage of NR.254 articles
- Configuration of ejecting devices
- Different password levels
- Machine condition and diagnostic indications (functioning, troubles, alarms)
- Weight or immediate error.
- Statistical indications with reference to the total values or to the single production batch.
- Pieces per minute
- Average production
- Conveyor speed (meters per min)
- Graphic display of the flow and classification of the weights
- Efficiency
- List of the non-weighable items
- Standard deviation
- Statistical distribution (Gaussian curve)
- Total and single batch values.
- Automatic adjustment of conveyors speed according to set parameters / items.
- Control of product length and minimum distance between one product and the next one.
- Machine setting by means of automatic statistical and dynamic calibration.
- Automatic zero-setting with 4% maximum range related to the maximum load.
- Control of consecutive rejects.
Touch-screen colourful display 12”.
- Language options: Italian, French, English.
- ON/OFF controls included in the operator panel.
- Alarms indicators with No. 2 light signals, the configuration of which can be chosen depending on machine working and/or relevant alarms.
- Flexural load cell, Protection IP 65, 9,000 div
- Minimum weight value: 50 g.
- Maximum weight value: 1.200 g.
- Metrical verification division ’e’: 0,5
- Storage of NR.254 articles
- Configuration of ejecting devices
- Different password levels